Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 82 of 82 items found.

  • ZZ Power Booster 1200V/3000V

    ZZ Booster-Transmitter - ZZ Resistivity Imaging Pty. Ltd.

    *3,000W output power in 2 adjustable voltage ranges ( 400V/7.5A, 1,200V/2.5A), the FlashRES booster transmitter is particular useful for surveys in high resistive areas or IP surveys.*When the FlashRES booster transmitter is connected FlashRES-UNIVERSAL, for each current injection, the system could collect 61 voltage measurement, this greatly increases the data collection speed.*Uses two standard 12V batteries connect in series as input power source*The FlashRES booster transmitter is designed for heavy duty usage, the instrument is shock, water and dust proof.*Light-weight and easily mobilised

  • Transforming Analog Circuit Breaker Testers

    MAC-21 - ETI Precision

    The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Advanced Primary Injection Test Set

    PI-2500 - ETI Precision

    The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TW Series - IBEKO Power AB

    RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.

  • Fibre Channel PXI Express Test & Simulation Instrument

    PXIe-FC4 - Avionics Interface Technologies

    3U PXIe form factor will fit into any PXIe or hybrid slot - Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Triggering and Filtering - Error Injection on any Header or Payload Parameter - Data Capture to on-board memory or disk file - Live Capture and Current Value Monitoring - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent Analyzer - Supports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Supports HS-1760E applications, including AS5653, AS5625, and AS5627fcXplorer Windows-based FC Simulator and Analyzer Test Software

Get Help